The NSN 5950-01-260-5172 part numbers such as 1C7824-1, 4C3578-1, 5034-111 manufactured by Ge Aviation Systems Llc, Raytheon Company are available in RFQ Experts’ inventory. An ASAP Semiconductor owned and operated website, RFQ Experts has over six billion parts in its inventory for NSN 5950-01-260-5172. ASAP is committed to streamlining the parts procurement process for our customers, making it easy for them to search through billions of parts to find exactly what they are looking for. We have dedicated account managers ready to solve procurement issues our clients face, whether it’s a need for obsolete parts, or an aircraft on ground situation. As an AS9120B, ISO 9001:2015, and FAA AC 0056B certified company, each and every part that we ship goes through numerous quality checks and inspections, to ensure that we sell only the highest-quality parts.
Alternative NSN: 5950-01-260-5172 |
Item Name: Transformer Power |
Federal Supply Class (FSC): 5950 Coils and Transformers |
NIIN: 012605172 |
NCB Code: USA (01) |
Manufacturers: Ge Aviation Systems Llc, Raytheon Company |
Part No | NSN | Item Name | QTY | RFQ |
---|---|---|---|---|
1C7824-1 | 5950-01-260-5172 | transformer power | Avl | RFQ |
4C3578-1 | 5950-01-260-5172 | transformer power | Avl | RFQ |
5034-111 | 5950-01-260-5172 | transformer power | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ACZB | FREQUENCY RATING | 60.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 4.1 VOLT-AMPERE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 1.000 INCHES MAXIMUM |
ADAT | BODY WIDTH | 1.000 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 1.000 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 155.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AXGY | MOUNTING METHOD | TERMINAL SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 10.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 250.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 0.1 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 3.99 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 10.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 10.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 15.96 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 6 PIN |
You Can Click Here to Get Quote For Your Required Aircraft Parts Within 15 Minutes.
Request for Quote