The NSN 5950-00-581-9199 part numbers such as 2A2-244, 631198, BTC2902, D631198, W10194 manufactured by Emerson Electric Co, Alliant Techsystems Operations Llc, Berkshire Transformers, Rohde And Schwarz Usa Inc, Unisys Ltd are available in RFQ Experts’ inventory. An ASAP Semiconductor owned and operated website, RFQ Experts has over six billion parts in its inventory for NSN 5950-00-581-9199. ASAP is committed to streamlining the parts procurement process for our customers, making it easy for them to search through billions of parts to find exactly what they are looking for. We have dedicated account managers ready to solve procurement issues our clients face, whether it’s a need for obsolete parts, or an aircraft on ground situation. As an AS9120B, ISO 9001:2015, and FAA AC 0056B certified company, each and every part that we ship goes through numerous quality checks and inspections, to ensure that we sell only the highest-quality parts.
Alternative NSN: 5950-00-581-9199 |
Item Name: Transformer Power |
Federal Supply Class (FSC): 5950 Coils and Transformers |
NIIN: 005819199 |
NCB Code: USA (00) |
Manufacturers: Emerson Electric Co, Alliant Techsystems Operations Llc, Berkshire Transformers, Rohde And Schwarz Usa Inc, Unisys Ltd |
Emerson Electric Co | Alliant Techsystems Operations.. | Berkshire Transformers |
Rohde And Schwarz Usa Inc | Unisys Ltd |
Part No | NSN | Item Name | QTY | RFQ |
---|---|---|---|---|
2A2-244 | 5950-00-581-9199 | transformer power | Avl | RFQ |
631198 | 5950-00-581-9199 | transformer power | Avl | RFQ |
BTC2902 | 5950-00-581-9199 | transformer power | Avl | RFQ |
D631198 | 5950-00-581-9199 | transformer power | Avl | RFQ |
W10194 | 5950-00-581-9199 | transformer power | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.094 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.890 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.922 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTD | MOUNTING SLOT WIDTH | 0.213 INCHES MINIMUM SINGLE GROUP AND 0.223 INCHES MAXIMUM SINGLE GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 1.0 KILOHERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 5.000 INCHES MAXIMUM |
ADAT | BODY WIDTH | 4.031 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 4.500 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 170.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | SLOT SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 6 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 2.0 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 2.8 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 300.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 600.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 10.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 17.6 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 3.78 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 565.5 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 45.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY AND 705.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY AND 1.29 AC KILOVOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY AND 1.88 AC KILOVOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 5.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 56.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
FEAT | SPECIAL FEATURES | ONE PRIMARY WINDING AND SIX SECONDARY WINDINGS |
TEST | TEST DATA DOCUMENT | 56232-631198 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI |
TTQY | TERMINAL TYPE AND QUANTITY | 19 TAB, SOLDER LUG |