The NSN 5925-01-170-1758 part numbers such as 1140-G151-P7M1-018808-1A, 44-800P, 44-800P10 1AMP, 44-800P1AMP manufactured by Oakland Industries Ltd are available in RFQ Experts’ inventory. An ASAP Semiconductor owned and operated website, RFQ Experts has over six billion parts in its inventory for NSN 5925-01-170-1758. ASAP is committed to streamlining the parts procurement process for our customers, making it easy for them to search through billions of parts to find exactly what they are looking for. We have dedicated account managers ready to solve procurement issues our clients face, whether it’s a need for obsolete parts, or an aircraft on ground situation. As an AS9120B, ISO 9001:2015, and FAA AC 0056B certified company, each and every part that we ship goes through numerous quality checks and inspections, to ensure that we sell only the highest-quality parts.
Alternative NSN: 5925-01-170-1758 |
Item Name: Circuit Breaker |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 011701758 |
NCB Code: USA (01) |
Manufacturers: Oakland Industries Ltd |
Part No | NSN | Item Name | QTY | RFQ |
---|---|---|---|---|
1140-G151-P7M1-018808-1A | 5925-01-170-1758 | circuit breaker | Avl | RFQ |
44-800P | 5925-01-170-1758 | circuit breaker | Avl | RFQ |
44-800P10 1AMP | 5925-01-170-1758 | circuit breaker | Avl | RFQ |
44-800P1AMP | 5925-01-170-1758 | circuit breaker | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
MRC | Decoded Requirement | Clear Text Reply |
AAQL | Body Style | SINGLE POLE TYPE |
CPLM | Maximum Continuous Load Current Rating Per Pole | 1.0 AMPERES AC AND |
AFJN | Fragility Factor | MODERATELY RUGGED |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC AND |
ABXD | Bushing Length | 0.650 INCHES NOMINAL |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 28.0 DC SINGLE LOCATION |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 100.0 DC SINGLE LOCATION |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 100.0 AC AND |
CPRJ | Trip Release Method | THERMAL SINGLE LOCATION |
ADAT | Body Width | 0.570 INCHES NOMINAL |
FREQ | Frequency In Hertz | 60.0 SINGLE LOCATION |
AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING |
AKPX | Pole Quantity | 1 |
CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
CPRQ | Reset Method | MANUAL |
CRCF | Trip Release Ambient Temp Rating | 70.0 DEG FAHRENHEIT NOMINAL SINGLE LOCATION |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 SINGLE LOCATION |
CPRT | Manual Actuator Type And Quantity | 1 PUSH BUTTON |
CPRW | Actuator Function | TRIP-RESET |
ADTV | Case Material | PLASTIC |
CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
CPRX | Actuator Position Designation | AT POLE ONE |
CQJX | Nominal Thread Size | 0.375 INCHES |
AJWX | Mounting Surface To Terminal End Distance | 2.260 INCHES NOMINAL |
ADAQ | Body Length | 1.140 INCHES NOMINAL |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.780 INCHES NOMINAL |
THSD | Thread Series Designator | UNS |
TTQY | Terminal Type And Quantity | 2 PIN |
PKWT | Unpackaged Unit Weight | 0.062 POUNDS |
CPLM | Maximum Continuous Load Current Rating Per Pole | 1.0 AMPERES DC SINGLE LOCATION |
CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 40.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 10.000 MINIMUM AT 200 PCT AND |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CMLP | Thread Quantity Per Inch | 27 |
CQXF | Inclosure Protection Type For Which Designed | GENERAL PURPOSE |
You Can Click Here to Get Quote For Your Required Aircraft Parts Within 15 Minutes.
Request for Quote