The NSN 5925-00-890-7487 part numbers such as AP6-267-1 manufactured by Sensata Technologies Inc are available in RFQ Experts’ inventory. An ASAP Semiconductor owned and operated website, RFQ Experts has over six billion parts in its inventory for NSN 5925-00-890-7487. ASAP is committed to streamlining the parts procurement process for our customers, making it easy for them to search through billions of parts to find exactly what they are looking for. We have dedicated account managers ready to solve procurement issues our clients face, whether it’s a need for obsolete parts, or an aircraft on ground situation. As an AS9120B, ISO 9001:2015, and FAA AC 0056B certified company, each and every part that we ship goes through numerous quality checks and inspections, to ensure that we sell only the highest-quality parts.
Alternative NSN: 5925-00-890-7487 |
Item Name: Circuit Breaker |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 008907487 |
NCB Code: USA (00) |
Manufacturers: Sensata Technologies Inc |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | SINGLE POLE TYPE |
ABXD | BUSHING LENGTH | 0.450 NOMINAL MILS AND 0.550 NOMINAL CENTIMETERS |
ADAQ | BODY LENGTH | 1.562 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.625 INCHES MAXIMUM |
ADTV | CASE MATERIAL | METAL |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.700 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 1 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 3.0 AMPERES DC SINGLE LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 50.0 DC SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 500.0 DC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 115.0 SINGLE LOCATION |
CPRP | ULTIMATE TRIP TIME PER POLE IN SECONDS | 0.200 MINIMUM SINGLE LOCATION AND 7.000 MAXIMUM SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
CQJX | NOMINAL THREAD SIZE | 0.375 INCHES |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.050 AT 800 PCT PASCAL SINGLE LOCATION AND 0.950 18 STAGE PASCAL SINGLE LOCATION |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | MOISTURE RESISTANT |
TEST | TEST DATA DOCUMENT | 18876-10182040 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA |
THSD | THREAD SERIES DESIGNATOR | UNEF |
TTQY | TERMINAL TYPE AND QUANTITY | 2 SCREW |
You Can Click Here to Get Quote For Your Required Aircraft Parts Within 15 Minutes.
Request for Quote