The NSN 5925-00-448-2252 part numbers such as 10 30460 75 manufactured by The Boeing Company are available in RFQ Experts’ inventory. An ASAP Semiconductor owned and operated website, RFQ Experts has over six billion parts in its inventory for NSN 5925-00-448-2252. ASAP is committed to streamlining the parts procurement process for our customers, making it easy for them to search through billions of parts to find exactly what they are looking for. We have dedicated account managers ready to solve procurement issues our clients face, whether it’s a need for obsolete parts, or an aircraft on ground situation. As an AS9120B, ISO 9001:2015, and FAA AC 0056B certified company, each and every part that we ship goes through numerous quality checks and inspections, to ensure that we sell only the highest-quality parts.
Alternative NSN: 5925-00-448-2252 |
Item Name: Circuit Breaker |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 004482252 |
NCB Code: USA (00) |
Manufacturers: The Boeing Company |
Part No | NSN | Item Name | QTY | RFQ |
---|---|---|---|---|
10 30460 75 | 5925-00-448-2252 | circuit breaker | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | SINGLE POLE TYPE |
ABXD | BUSHING LENGTH | 0.468 INCHES NOMINAL |
ADAQ | BODY LENGTH | 2.189 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.760 INCHES MAXIMUM |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.810 INCHES NOMINAL |
AKPX | POLE QUANTITY | 1 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 75.0 AMPERES DC SINGLE LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 30.0 DC SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 6000.0 DC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | THERMAL SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 24.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 70.000 MAXIMUM AT 200 PCT SINGLE LOCATION AND 3.300 MINIMUM AT 400 PCT SINGLE LOCATION AND 12.000 MAXIMUM AT 400 PCT SINGLE LOCATION |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 77.0 DEG FAHRENHEIT NOMINAL SINGLE LOCATION |
You Can Click Here to Get Quote For Your Required Aircraft Parts Within 15 Minutes.
Request for Quote