The NSN 5925-00-236-0758 part numbers such as 3P60, NA3P60, NA3P60 manufactured by Challenger Electrical Equipment Corp, E C C Spares And Services Electro Work are available in RFQ Experts’ inventory. An ASAP Semiconductor owned and operated website, RFQ Experts has over six billion parts in its inventory for NSN 5925-00-236-0758. ASAP is committed to streamlining the parts procurement process for our customers, making it easy for them to search through billions of parts to find exactly what they are looking for. We have dedicated account managers ready to solve procurement issues our clients face, whether it’s a need for obsolete parts, or an aircraft on ground situation. As an AS9120B, ISO 9001:2015, and FAA AC 0056B certified company, each and every part that we ship goes through numerous quality checks and inspections, to ensure that we sell only the highest-quality parts.
Alternative NSN: 5925-00-236-0758 |
Item Name: Circuit Breaker |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 002360758 |
NCB Code: USA (00) |
Manufacturers: Challenger Electrical Equipment Corp, E C C Spares And Services Electro Work |
Part No | NSN | Item Name | QTY | RFQ |
---|---|---|---|---|
3P60 | 5925-00-236-0758 | circuit breaker | Avl | RFQ |
NA3P60 | 5925-00-236-0758 | circuit breaker | Avl | RFQ |
NA3P60 | 5925-00-236-0758 | circuit breaker | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
ADAQ | BODY LENGTH | 3 344 INCHES NOMINAL |
ADAT | BODY WIDTH | 3 000 INCHES NOMINAL |
ADAU | BODY HEIGHT | 2 312 INCHES NOMINAL |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1 000 INCHES NOMINAL |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJEC | BOSS HEIGHT | 0 220 INCHES NOMINAL |
AKPX | POLE QUANTITY | 3 |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 TERMINAL |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 60 0 AMPERES AC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240 0 AC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 10000 0 AC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125 0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 20 000 MINIMUM AT 200 PCT AND 60 000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | GENERAL PURPOSE |
CWJK | CASE MATERIAL | PLASTIC |
FREQ | FREQUENCY IN HERTZ | 60 0 ALL LOCATIONS |
TTQY | TERMINAL TYPE AND QUANTITY | 3 CLIP AND 3 COMPRESSION |