The NSN 5925-00-026-4767 part numbers such as 0624A0392, 12045387, 16913P11, 195900, 20L10 manufactured by Arrow Master Incorporated, Bcp Construction Products, M R S Mfg Co, Fwd Seagrave Holdings Lp, Barber Greene Co are available in RFQ Experts’ inventory. An ASAP Semiconductor owned and operated website, RFQ Experts has over six billion parts in its inventory for NSN 5925-00-026-4767. ASAP is committed to streamlining the parts procurement process for our customers, making it easy for them to search through billions of parts to find exactly what they are looking for. We have dedicated account managers ready to solve procurement issues our clients face, whether it’s a need for obsolete parts, or an aircraft on ground situation. As an AS9120B, ISO 9001:2015, and FAA AC 0056B certified company, each and every part that we ship goes through numerous quality checks and inspections, to ensure that we sell only the highest-quality parts.
Alternative NSN: 5925-00-026-4767 |
Item Name: Circuit Breaker |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 000264767 |
NCB Code: USA (00) |
Manufacturers: Arrow Master Incorporated, Bcp Construction Products, M R S Mfg Co, Fwd Seagrave Holdings Lp, Barber Greene Co, Linde Lift Truck Corp, Caterpillar Inc, Elliott Machine Works Inc, American Hoist And Derrick Co, American Standard Inc, Badger Fire Protection Inc, Vme Americas Inc, Clark Equipment Company, E C A Etablissement Central, Davey Compressor Co, Morris Material Handling Ltd, Sensata Technologies Inc, Pettibone Corp, Anthony York Co |
Part No | NSN | Item Name | QTY | RFQ |
---|---|---|---|---|
0624A0392 | 5925-00-026-4767 | circuit breaker | Avl | RFQ |
12045387 | 5925-00-026-4767 | circuit breaker | Avl | RFQ |
16913P11 | 5925-00-026-4767 | circuit breaker | Avl | RFQ |
195900 | 5925-00-026-4767 | circuit breaker | Avl | RFQ |
20L10 | 5925-00-026-4767 | circuit breaker | Avl | RFQ |
375MAF1 | 5925-00-026-4767 | circuit breaker | Avl | RFQ |
3M5999 | 5925-00-026-4767 | circuit breaker | Avl | RFQ |
4499 | 5925-00-026-4767 | circuit breaker | Avl | RFQ |
481525 | 5925-00-026-4767 | circuit breaker | Avl | RFQ |
485643 | 5925-00-026-4767 | circuit breaker | Avl | RFQ |
517323 | 5925-00-026-4767 | circuit breaker | Avl | RFQ |
519566 | 5925-00-026-4767 | circuit breaker | Avl | RFQ |
519566 | 5925-00-026-4767 | circuit breaker | Avl | RFQ |
5925000264767 | 5925-00-026-4767 | circuit breaker | Avl | RFQ |
60092 | 5925-00-026-4767 | circuit breaker | Avl | RFQ |
79Z622 | 5925-00-026-4767 | circuit breaker | Avl | RFQ |
C9115-5-15 | 5925-00-026-4767 | circuit breaker | Avl | RFQ |
LA1118 | 5925-00-026-4767 | circuit breaker | Avl | RFQ |
TC15-1447 | 5925-00-026-4767 | circuit breaker | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | SINGLE POLE TYPE |
ADAQ | BODY LENGTH | 2.000 INCHES NOMINAL |
ADAT | BODY WIDTH | 1.813 INCHES NOMINAL |
ADAU | BODY HEIGHT | 1.875 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.625 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.174 INCHES NOMINAL |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.566 INCHES MINIMUM AND 1.582 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AKPX | POLE QUANTITY | 1 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |
BBRG | III STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 15.0 AMPERES DC SINGLE LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 28.0 DC SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 575.0 DC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | THERMAL SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 138.0 SINGLE LOCATION |
CPRQ | RESET METHOD | AUTOMATIC |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 8.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | WATERPROOF AND VIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
TEST | TEST DATA DOCUMENT | 81349-MIL-C-13516 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTI |
TTQY | TERMINAL TYPE AND QUANTITY | 2 QUICK DISCONNECT, MALE |
ZZZK | SPECIFICATION/STANDARD DATA | 81349--13561/1 GOVERNMENT SPECIFICATION |