Part detail
Circuit Breaker
05A184-09NSN5925-01-182-1639CAGE1W025
Circuit Breaker
Detailed description
05A184-09 procurement notes
Circuit Breaker
Specifications
Reference data
Multi-line procurement
Sourcing more than one part?
Upload a bill of materials (BOM) or paste a list of part numbers — every line bundles into a single RFQ. No checkout, no payment.
Compliance
- AS9120:2025· Aerospace QMS
- ISO 9001:2015· Quality Management
- FAA AC 00-56B· Voluntary Industry Distributor Accreditation
- U.S. ONLY· Fulfillment
NSN Information for Part Number 05A184-09 with NSN 5925-01-182-1639, 5925011821639
Characteristics Data of NSN 5925-01-182-1639, 5925011821639
| MRC | Criteria | Characteristic |
|---|---|---|
| AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE" |
| ABXD | BUSHING LENGTH | 0.250 INCHES NOMINAL" |
| ADAQ | BODY LENGTH | 1.349 INCHES MAXIMUM" |
| ADAT | BODY WIDTH | 2.160 INCHES MAXIMUM" |
| ADAU | BODY HEIGHT | 2.170 INCHES MAXIMUM" |
| ADTV | CASE MATERIAL | PLASTIC" |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.750 INCHES NOMINAL" |
| AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.688 INCHES NOMINAL" |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED" |
| AKPX | POLE QUANTITY | 3" |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING" |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE" |
| CMLP | THREAD QUANTITY PER INCH | 32" |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 40.0 AMPERES AC ALL LOCATIONS" |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 120.0 AC ALL LOCATIONS" |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC ALL LOCATIONS" |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS" |
| CPRJ | TRIP RELEASE METHOD | THERMAL ALL LOCATIONS" |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS" |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 138.0 ALL LOCATIONS" |
| CPRQ | RESET METHOD | MANUAL" |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE" |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL" |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET" |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO" |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS" |
| CQJX | NOMINAL THREAD SIZE | 0.469 INCHES" |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 10.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 70.000 MAXIMUM AT 200 PCT ALL LOCATIONS" |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | SHOCK RESISTANT AND VIBRATION RESISTANT" |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS NOMINAL ALL LOCATIONS" |
| FREQ | FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS" |
| PKWT | UNPACKAGED UNIT WEIGHT | 127.0 GRAMS" |
| THSD | THREAD SERIES DESIGNATOR | UNS" |
| TTQY | TERMINAL TYPE AND QUANTITY | 6 SCREW" |
| AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE" |
| ABXD | BUSHING LENGTH | 0.250 INCHES NOMINAL" |
| ADAQ | BODY LENGTH | 1.349 INCHES MAXIMUM" |
| ADAT | BODY WIDTH | 2.160 INCHES MAXIMUM" |
| ADAU | BODY HEIGHT | 2.170 INCHES MAXIMUM" |
| ADTV | CASE MATERIAL | PLASTIC" |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.750 INCHES NOMINAL" |
| AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.688 INCHES NOMINAL" |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED" |
| AKPX | POLE QUANTITY | 3" |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING" |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE" |
| CMLP | THREAD QUANTITY PER INCH | 32" |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 40.0 AMPERES AC ALL LOCATIONS" |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 120.0 AC ALL LOCATIONS" |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC ALL LOCATIONS" |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS" |
| CPRJ | TRIP RELEASE METHOD | THERMAL ALL LOCATIONS" |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS" |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 138.0 ALL LOCATIONS" |
| CPRQ | RESET METHOD | MANUAL" |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE" |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL" |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET" |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO" |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS" |
| CQJX | NOMINAL THREAD SIZE | 0.469 INCHES" |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 10.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 70.000 MAXIMUM AT 200 PCT ALL LOCATIONS" |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | SHOCK RESISTANT AND VIBRATION RESISTANT" |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS NOMINAL ALL LOCATIONS" |
| FREQ | FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS" |
| PKWT | UNPACKAGED UNIT WEIGHT | 127.0 GRAMS" |
| THSD | THREAD SERIES DESIGNATOR | UNS" |
| TTQY | TERMINAL TYPE AND QUANTITY | 6 SCREW" |