Part detail
Resistor Fixed Composition
0524-89NSN5905-00-254-9201CAGE03956
Resistor Fixed Composition
Detailed description
0524-89 procurement notes
Resistor Fixed Composition
Specifications
Reference data
Multi-line procurement
Sourcing more than one part?
Upload a bill of materials (BOM) or paste a list of part numbers — every line bundles into a single RFQ. No checkout, no payment.
Compliance
- AS9120:2025· Aerospace QMS
- ISO 9001:2015· Quality Management
- FAA AC 00-56B· Voluntary Industry Distributor Accreditation
- U.S. ONLY· Fulfillment
NSN Information for Part Number 0524-89 with NSN 5905-00-254-9201, 5905002549201
Characteristics Data of NSN 5905-00-254-9201, 5905002549201
| MRC | Criteria | Characteristic |
|---|---|---|
| AAPP | ELECTRICAL RESISTANCE | 47.000 KILOHMS" |
| AAPQ | RESISTANCE TOLERANCE IN PERCENT | -5.000/+5.000" |
| AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 70.0" |
| AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 130.0" |
| AAQZ | INCLOSURE METHOD | ENCAPSULATED" |
| AARB | TERMINAL TYPE | WIRE LEAD" |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
| ABJT | TERMINAL LENGTH | 1.500 INCHES NOMINAL" |
| ABPM | BODY DIAMETER | 0.138 INCHES NOMINAL" |
| ADAQ | BODY LENGTH | 0.375 INCHES NOMINAL" |
| AEFB | POWER DISSIPATION RATING IN WATTS | 0.500 FREE AIR" |
| STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END" |
| TEST | TEST DATA DOCUMENT | 81349-MIL-R-11 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING" |
| ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-11/3D GOVERNMENT SPECIFICATION" |
| AAPP | ELECTRICAL RESISTANCE | 47.000 KILOHMS" |
| AAPQ | RESISTANCE TOLERANCE IN PERCENT | -5.000/+5.000" |
| AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 70.0" |
| AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 130.0" |
| AAQZ | INCLOSURE METHOD | ENCAPSULATED" |
| AARB | TERMINAL TYPE | WIRE LEAD" |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
| ABJT | TERMINAL LENGTH | 1.500 INCHES NOMINAL" |
| ABPM | BODY DIAMETER | 0.138 INCHES NOMINAL" |
| ADAQ | BODY LENGTH | 0.375 INCHES NOMINAL" |
| AEFB | POWER DISSIPATION RATING IN WATTS | 0.500 FREE AIR" |
| STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END" |
| TEST | TEST DATA DOCUMENT | 81349-MIL-R-11 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING" |
| ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-11/3D GOVERNMENT SPECIFICATION" |