Part detail
Transformer Power
ST30150NSN5950-00-462-5832CAGE11447
Transformer Power
Detailed description
ST30150 procurement notes
Transformer Power
Specifications
Reference data
Multi-line procurement
Sourcing more than one part?
Upload a bill of materials (BOM) or paste a list of part numbers — every line bundles into a single RFQ. No checkout, no payment.
Compliance
- AS9120:2025· Aerospace QMS
- ISO 9001:2015· Quality Management
- FAA AC 00-56B· Voluntary Industry Distributor Accreditation
- U.S. ONLY· Fulfillment
NSN Information for Part Number ST30150 with NSN 5950-00-462-5832, 5950004625832
Characteristics Data of NSN 5950-00-462-5832, 5950004625832
| MRC | Criteria | Characteristic |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT |
| ABHP | OVERALL LENGTH | 2.440 INCHES MAXIMUM |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.985 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.015 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.090 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.180 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKW | OVERALL HEIGHT | 2.690 INCHES MAXIMUM |
| ABMK | OVERALL WIDTH | 2.120 INCHES MAXIMUM |
| ACZB | FREQUENCY RATING | 380.0 HERTZ MINIMUM SINGLE COMPONENT AND 1000.0 HERTZ MAXIMUM SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ACZX | WINDING SHIELDING METHOD | CORE GROUNDED AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
| BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
| CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
| CRBZ | WINDING OPERATING CURRENT | 1.24 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| CRBZ | WINDING OPERATING CURRENT | 130.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 55.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| CRMJ | WINDING POWER RATING | 16.9 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
| CRMJ | WINDING POWER RATING | 16.9 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY142.6 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY62.4 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
| CRMJ | WINDING POWER RATING | 62.4 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY16.9 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 308.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 308.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY480.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 480.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY308.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
| TTQY | TERMINAL TYPE AND QUANTITY | 9 TAB, SOLDER LUG |