Part detail
Resistor Variable N
058-044NSN5905-00-154-7024CAGE73138
Resistor Variable N
Detailed description
058-044 procurement notes
Resistor Variable N
Specifications
Reference data
Multi-line procurement
Sourcing more than one part?
Upload a bill of materials (BOM) or paste a list of part numbers — every line bundles into a single RFQ. No checkout, no payment.
Compliance
- AS9120:2025· Aerospace QMS
- ISO 9001:2015· Quality Management
- FAA AC 00-56B· Voluntary Industry Distributor Accreditation
- U.S. ONLY· Fulfillment
NSN Information for Part Number 058-044 with NSN 5905-00-154-7024, 5905001547024
Characteristics Data of NSN 5905-00-154-7024, 5905001547024
| MRC | Criteria | Characteristic |
|---|---|---|
| AAPN | SECTION QUANTITY | 1 |
| AAQL | BODY STYLE | RECTANGULAR |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABJT | TERMINAL LENGTH | 0.312 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 0.245 INCHES NOMINAL |
| ADAT | BODY WIDTH | 0.290 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 0.360 INCHES NOMINAL |
| AEDZ | SHAFT BEARING TYPE | SLEEVE |
| AEFD | ACTUATOR TYPE | FLUSH DRIVE WITH SLOT-HOLE |
| AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 240.0 NOMINAL |
| AEFK | MAXIMUM STARTING TORQUE | 5.00 INCH-OUNCES |
| AEFL | MAXIMUM RUNNING TORQUE | 5.00 INCH-OUNCES |
| AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.200 INCHES NOMINAL |
| APXH | TERMINAL LOCATION | LOWER ADJACENT SIDE TWO ROWS |
| AXGY | MOUNTING METHOD | TERMINAL |
| AYQR | CENTER TO CENTER DISTANCE BETWEEN TERMINAL ROWS | 0.100 INCHES NOMINAL |
| CBBL | FEATURES PROVIDED | NONMETALLIC SHAFT |
| CQCC | ELECTRICAL RESISTANCE PER SECTION | 2.0 KILOHMS SINGLE SECTION |
| CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 260.0 NOMINAL |
| CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.100 INCHES NOMINAL |
| CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 150.0 SINGLE SECTION |
| CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -100.0 TO 100.0 SINGLE SECTION |
| CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.5 FREE AIR SINGLE SECTION |
| CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -20.0 TO 20.0 SINGLE SECTION |
| CRSX | ACTUATOR TRAVEL CONTROL FEATURE | STOPS |
| CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 85.0 SINGLE SECTION |
| TEST | TEST DATA DOCUMENT | 30890-40-001030 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DR |
| TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
