Part detail
Resistor Thermal
42TD2NSN5905-00-917-5598CAGE90634
Resistor Thermal
Detailed description
42TD2 procurement notes
Resistor Thermal
Specifications
Reference data
Multi-line procurement
Sourcing more than one part?
Upload a bill of materials (BOM) or paste a list of part numbers — every line bundles into a single RFQ. No checkout, no payment.
Compliance
- AS9120:2025· Aerospace QMS
- ISO 9001:2015· Quality Management
- FAA AC 00-56B· Voluntary Industry Distributor Accreditation
- U.S. ONLY· Fulfillment
NSN Information for Part Number 42TD2 with NSN 5905-00-917-5598, 5905009175598
Characteristics Data of NSN 5905-00-917-5598, 5905009175598
| MRC | Criteria | Characteristic |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKW | OVERALL HEIGHT | 2.150 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 0.150 INCHES NOMINAL |
| ADAT | BODY WIDTH | 0.060 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 0.150 INCHES NOMINAL |
| AEBT | TERMINAL DIAMETER | 0.010 INCHES NOMINAL |
| AEHY | AMBIENT TEMP AT FULL RATED POWER | 25.0 DEG CELSIUS |
| AEHZ | MAXIMUM OPERATING TEMP | 105.0 DEG CELSIUS |
| AEJA | THERMAL TIME CONSTANT IN SECONDS | 6.0 |
| AEJB | POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 3.5 |
| AEJC | ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | 4.40 |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -30.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -55.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.4 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 2.0 MEGOHMS 1ST RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 358.4 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 65.6 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 7.2 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -10.0/+10.0 1ST RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -2.0/+2.0 3RD RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -2.0/+2.0 4TH RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -7.0/+7.0 5TH RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -8.0/+8.0 2ND RESISTANCE-TEMPERATURE POINT |
| AKNA | INCLOSURE TYPE | ENCAPSULATED |
| CQWD | III ZERO POWER RESISTANCE | 20.000 KILOHMS |
| CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0/+10.0 |
| CTGT | REFERENCE TEMP IN DEG CELSIUS | 25.0 |
| STYL | STYLE DESIGNATOR | BEAD IN CAN |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |