Part detail
Transformer Power
369B206G01NSN5950-00-600-0840CAGE19899
Transformer Power
Detailed description
369B206G01 procurement notes
Transformer Power
Specifications
Reference data
Multi-line procurement
Sourcing more than one part?
Upload a bill of materials (BOM) or paste a list of part numbers — every line bundles into a single RFQ. No checkout, no payment.
Compliance
- AS9120:2025· Aerospace QMS
- ISO 9001:2015· Quality Management
- FAA AC 00-56B· Voluntary Industry Distributor Accreditation
- U.S. ONLY· Fulfillment
NSN Information for Part Number 369B206G01 with NSN 5950-00-600-0840, 5950006000840
Characteristics Data of NSN 5950-00-600-0840, 5950006000840
| MRC | Criteria | Characteristic |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.320 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 4.440 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.690 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.810 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABTD | MOUNTING SLOT WIDTH | 0.312 INCHES NOMINAL SINGLE GROUP |
| ACZB | FREQUENCY RATING | 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| ADAQ | BODY LENGTH | 5.190 INCHES MINIMUM AND 5.310 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 5.000 INCHES MAXIMUM |
| ADAU | BODY HEIGHT | 4.688 INCHES MINIMUM AND 4.812 INCHES MAXIMUM |
| AGAV | END ITEM IDENTIFICATION | WSD: GENERATOR SET, 30 KW, 60 HZ, SKID-MOUNTED (3ID) (MEP-005A); GENERATOR, 15 KW, DIESEL, MILITARY STANDARD FAMILY; MAINT FACILITY, NIGHT SIGHT (NSMF), TAM E10227; AIRCRAFTS, STRATOFORTRESS B-52 AND B-1B |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND SLOT SINGLE GROUP |
| BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
| CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
| CWJS | WINDING OPERATING VOLTAGE | 124.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 208.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| FEAT | SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL |
| TTQY | TERMINAL TYPE AND QUANTITY | 5 TAB, SOLDER LUG AND 1 WIRE LEAD W/LUG |